上海口腔医学 ›› 2022, Vol. 31 ›› Issue (4): 354-358.doi: 10.19439/j.sjos.2022.04.004

• 论著 • 上一篇    下一篇

机用镍钛器械根管预备过程中加入连续根管外冲洗对根管内液体置换的影响

郭林溪, 李向芬, 赵苑汐, 苏勤   

  1. 口腔疾病研究国家重点实验室,国家口腔疾病临床医学研究中心, 四川大学华西口腔医院 牙体牙髓病科,四川 成都 610041
  • 收稿日期:2020-10-09 修回日期:2021-01-12 出版日期:2022-08-25 发布日期:2022-08-30
  • 通讯作者: 苏勤,E-mail:susan_sq@hotmail.com
  • 作者简介:郭林溪(1995-),女,硕士,住院医师,E-mail: glx_0203@163.com
  • 基金资助:
    四川省科技厅重点研发项目(2018SZ0129)

Effect of continuous flushing out of root canal on fluid replacement in root canal during mechanical preparation using Ni-Ti instrument

GUO Lin-xi, LI Xiang-fen, ZHAO Yuan-xi, SU Qin   

  1. State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Cariology and Endodontics, West China Hospital of Stomatology, Sichuan University. Chengdu 610041, Sichuan Province, China
  • Received:2020-10-09 Revised:2021-01-12 Online:2022-08-25 Published:2022-08-30

摘要: 目的: 评估机械预备过程中加入连续根管外冲洗对根管内液体置换的影响。方法: 根据根管预备过程中是否加入连续根管外冲洗,将60个标准化树脂模块分为5个实验组。在标准化树脂模块中注入纯黑墨水,完成各实验组的预备和冲洗方案后,测量每个实验组标化根管模块内剩余液体的吸光度(A)值,判断根管内液体置换情况;同时计算流体力学模型模拟根管锉在根管内做上下运动时根管内液体的流场。采用SPSS 19.0软件包对数据进行统计学分析。结果: 机动预备过程中加入连续根管外冲洗的3个实验组,根管内剩余液体的A值显著低于不加入根管外冲洗的实验组(P<0.05),但3个实验组组间无显著差异(P>0.05)。计算流体力学模型显示,加入连续根管外冲洗后,在根管中部存在液体的“有效返流区”,部分置换根管内液体;并且外冲洗进入根管内的液体通过锉的上下运动可以被输送至根尖区。结论: 机动预备过程中连续根管外冲洗进入根管内的液体,可部分替换原根管内溶液,稀释、改善根管内环境,对后续常规根管冲洗起到辅助作用。

关键词: 根管外冲洗, 镍钛器械, 计算流体力学, 液体置换

Abstract: PURPOSE: To evaluate the effect of continuous flushing out of the canal on fluid exchange in the root canal during mechanical preparation. METHODS: Sixty resin blocks with standardized root canals were divided into 5 experimental groups according to whether continuous flushing was performed during mechanical preparation. Injecting pure black ink into the root canals before each file preparation,the liquid exchange was calculated by measuring the absorbance value of the remaining liquid after performing different preparation and irrigation schemes. Meanwhile, computational fluid dynamics model was established which simulated the flow field in the canal when the file moved up-and-down. SPSS 19.0 software package was used for statistical analysis of the data. RESULTS: The absorbance value of the remaining fluid in the root canal of the three groups in which continuous flushing was performed during mechanical preparation differed significantly from the group without continuous flushing(P<0.05), but no significant difference among the three groups (P>0.05). Computer simulation confirmed that the “efficient regurgitation area” existed in the middle part of the root canal and fluid could be gradually transported to the apical area by the file's up-and-down motion. CONCLUSIONS: Continuous flushing out of the canal during mechanical preparation can replace the original solution in the canal partly, which is beneficial to conventional irrigation for cleaning of the root canal.

Key words: Continuous flushing out of the canal, Nickel titanium instrument, Computational fluid dynamics, Fluid replacement

中图分类号: