[1] 中华口腔医学会.第四次全国口腔健康流行病学调查报告[M].北京: 人民卫生出版社, 2018:12-13. [2] Beldüz Kara N, Yilmaz Y.Assessment of oral hygiene and periodontal health around posterior primary molars after their restoration with various crown types[J]. Int J Paediatr Dent, 2014, 24(4): 303-313. [3] Santamaria RM, Innes NP, Machiulskiene V, et al.Caries management strategies for primary molars[J]. J Dent Res, 2014, 93(11): 1062-1069. [4] Kindelan SA, Day P, Nichol R, et al.UK National clinical guidelines in paediatric dentistry: stainless steel preformed crowns for primary molars[J]. Int J Paediatr Dent, 2008, 18(Suppl 1): 20-28. [5] Gallagher S, O'Connell BC, O'Connell AC. Assessment of occlusion after placement of stainless steel crowns in children-a pilot study[J]. J Oral Rehabil, 2014, 41(10): 730-736. [6] Osborn JW.The disc of the human temporomandibular joint: design, function and failure[J]. J Oral Rehabil, 1985, 12(4): 279-293. [7] Cervino G, Fiorillo L, Arzukanyan AV, et al.Application of bioengineering devices for stress evaluation in dentistry: the last 10 years FEM parametric analysis of outcomes and current trends[J]. Minerva Stomatol, 2020, 69(1): 55-62. [8] Joseph RM, Rao AP, Srikant N, et al.Evaluation of changes in the occlusion and occlusal vertical dimension in children following the placement of preformed metal crowns using the hall technique[J]. J Clin Pediatr Dent, 2020, 44(2):130-134. [9] Kaya MS, Kınay Taran P, Bakkal M.Temporomandibular dysfunction assessment in children treated with the hall technique:a pilot study[J]. Int J Paediatr Dent, 2020, 30(4): 429-435. [10] Nair K, Chikkanarasaiah N, Poovani S, et al.Digital occlusal analysis of vertical dimension and maximum intercuspal position after placement of stainless steel crown using hall technique in children[J]. Int J Paediatr Dent, 2020, 30(6): 805-815. [11] van der Zee V, van Amerongen WE. Short communication: influence of preformed metal crowns(hall technique)on the occlusal vertical dimension in the primary dentition[J]. Eur Arch Paediatr Dent, 2010, 11(5): 225-227. [12] Guduk OF, Sivrikaya EC, Yilmaz N, et al.Is zirconium or stainless steel the most suitable crown material for less dentin stress in endodontically treated teeth?[J]. Technol Health Care, 2022, 30(5): 1199-1207. [13] Owais AI, Shaweesh M, Abu Alhaija ES.Maximum occlusal bite force for children in different dentition stages[J]. Eur J Orthod, 2013, 35(4): 427-433. [14] 胡凯, 张晔缨, 柳春明, 等. 模拟功能咬合时人颞下颌关节内的应力分布和位移特征[J].解放军医学杂志, 2003, 28(1): 63-65. [15] Faulkner MG, Hatcher DC, Hay A.A three-dimensional investigation of temporomandibular joint loading[J]. J Biomech, 1987, 20(10): 997-1002. [16] 刘路平, 由敬舜, 徐剑青, 等. 五种咬合情况下颞下颌关节负荷的三维有限元分析[J]. 中华口腔医学杂志, 1994, 29(6): 368-371. [17] Savoldelli C, Bouchard PO, Loudad R, et al.Stress distribution in the temporo-mandibular joint discs during jaw closing: a high-resolution three-dimensional finite-element model analysis[J]. Surg Radiol Anat, 2012, 34(5): 405-413. [18] dos Santos J Jr, Blackman RB, Nelson SJ. Vectorial analysis of the static equilibrium of forces generated in the mandible in centric occlusion, group function, and balanced occlusion relationships[J]. J Prosthet Dent, 1991, 65(4): 557-567. [19] Verma L, Passi S.Glass fibre-reinforced composite post and core used in decayed primary anterior teeth: a case report[J].Case Rep Dent, 2011: 864254. [20] Hegde KS, Suvarna RM, Bhat SS.Stress analysis in endodontically treated primary molar with and without stainless steel crown: a comparative finite element model study[J]. J Nat Sci Biol Med, 2019, 10(2): 202-208. [21] Mongini F.Remodelling of the mandibular condyle in the adult and its relationship to the condition of the dental arches[J]. Acta Anat (Basel), 1972, 82(3): 437-453. [22] Mongini F.Dental abrasion as a factor in remodeling of the mandibular condyle[J]. Acta Anat (Basel), 1975, 92(2): 292-300. [23] Arnett GW, Milam SB, Gottesman L.Progressive mandibular retrusion-idiopathic condylar resorption. part Ⅱ[J]. Am J Orthod Dentofacial Orthop, 1996, 110(2): 117-127. [24] 施宜君, 杨燃, 王艳, 等. 乳磨牙金属预成冠修复后咬合及颞下颌关节评估的临床研究[J].口腔疾病防治, 2022, 30(11): 785-791. [25] Prabhakar AR, Chakraborty A, Nadig B, et al.Finite element stress analysis of restored primary teeth: a comparative evaluation between stainless steel crowns and preformed zirconia crowns[J]. Int J Oral Health Sci, 2017, 7(1): 10-10. [26] American Academy of Pediatric Dentistry. Acquired temporomandibular disorders in infants, children, and adolescents[J]. Pediatr Dent, 2018, 40(6): 366-372. [27] 石伟华, 王丹丹, 唐忠旺, 等. 乳牙列个别正常牙尖交错位咬合接触的研究[J]. 中华口腔医学杂志, 2021, 56(9): 873-879. [28] Owais AI, Al-Battah AH, Abu Alhaija ES.Changes in occlusal bite force following placement of preformed metal crowns on primary molars in 4-6 years old children:a 6 months’follow-up pilot study[J]. Eur Arch Paediatr Dent, 2019, 20(1): 9-14. [29] 张人杰, 周翊翛, 郑东翔, 等. 患者主观感受和T-Scan咬合分析在牙列重度磨耗修复功能性评价中的作用[J]. 北京口腔医学, 2019, 27(1): 37-41. [30] Kamegai T, Tatsuki T, Nagano H, et al.A determination of bite force in northern Japanese children[J]. Eur J Orthod, 2005, 27(1): 53-57. [31] Gavião MB, Raymundo VG, Rentes AM.Masticatory performance and bite force in children with primary dentition[J]. Braz Oral Res, 2007, 21(2): 146-152. [32] Mountain G, Wood D, Toumba J.Bite force measurement in children with primary dentition[J]. Int J Paediatr Dent, 2011, 21(2): 112-118. [33] Savoldelli C, Bouchard PO, Manière-Ezvan A, et al.Comparison of stress distribution in the temporomandibular joint during jaw closing before and after symphyseal distraction:a finite element study[J]. Int J Oral Maxillofac Surg, 2012, 41(12): 1474-1482. |