[1] Pjetursson BE, Asgeirsson AG, Zwahlen M, et al.Improvements in implant dentistry over the last decade: comparison of survival and complication rates in older and newer publications[J]. Int J Oral Maxillofac Implants, 2014, 29(Suppl): 308-324. [2] Olerud E, Hagman-Gustafsson ML, Gabre P.Oral status, oral hygiene, and patient satisfaction in the elderly with dental implants dependent on substantial needs of care for daily living[J]. Spec Care Dentist, 2012, 32(2): 49-54. [3] Manzoor B, Suleiman M, Palmer RM.The effects of simulated bone loss on the implant-abutment assembly and likelihood of fracture: an in vitro study[J]. Int J Oral Maxillofac Implants, 2013, 28(3): 729-738. [4] Schulte JK, Coffey J.Comparison of screw retention of nine abutment systems: a pilot study[J]. Implant Dent, 1997, 6(1): 28-31. [5] Johansson G, Palmqvist S.Complications, supplementary treatment, and maintenance in edentulous arches with implant-supported fixed prostheses[J]. Int J Prosthodont, 1990, 3(1): 89-92. [6] Martin WC, Woody RD, Miller BH, et al.Implant abutment screw rotations and preloads for four different screw materials and surfaces[J]. J Prosthet Dent, 2001, 86(1): 24-32. [7] Mattheos N, Janda MS.Exotic encounters with dental implants: managing complications with unidentified systems[J]. Aust Dent J, 2012, 57(2): 236-242. [8] Kitagawa T, Tanimoto Y, Odaki M, et al.Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system[J]. J Biomed Mater Res B Appl Biomater, 2005, 75(2): 457-463. [9] Kim KS, Lim YJ, Kim MJ, et al.Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection[J]. Clin Oral Implants Res, 2011, 22(8): 834-839. [10] Yousef H, Luke A, Ricci J, et al.Analysis of changes in implant screws subject to occlusal loading: a preliminary analysis[J]. Implant Dent, 2005, 14(4): 378-382. [11] Kim SK, Koak JY, Heo SJ, et al.Screw loosening with interchangeable abutments in internally connected implants after cyclic loading[J]. Int J Oral Maxillofac Implants, 2012, 27(1): 42-47. [12] Hamilton A, Judge RB, Palamara JE, et al.Evaluation of the fit of cad/cam abutments[J]. Int J Prosthodont, 2013, 26(4): 370-380. [13] Scarano A, Quaranta M, Traini T, et al.Sem and fractography analysis of screw thread loosening in dental implants[J]. Int J Immunopatyol Pharmacl, 2007, 20(Suppl 1): 19-22. [14] Cardoso M, Torres MF, Lourenco EJ, et al.Removal evaluation of prosthetic screws after tightening and loosening cycles: an in vitro study[J]. Clin Oral Implants Res, 2012, 23(4): 475-480. [15] Darendeliler MA, Zea A, Shen G, et al.Effects of pulsed electromagnetic field vibration on tooth movement induced by magnetic and mechanical forces: a preliminary study[J]. Aust Dent J, 2007, 52(4): 282-287. |