上海口腔医学 ›› 2016, Vol. 25 ›› Issue (4): 431-437.

• 论 著 • 上一篇    下一篇

2种支架设计对基牙及相关组织受力的三维有限元分析

柏黎明1, 李国强2, 张强1, 董晛3   

  1. 1.上海市口腔病防治院 口腔修复工艺科,2.中日友好诊室,上海 200031; 3.上海健康医学院医学技术学院,上海 201318
  • 收稿日期:2015-08-10 出版日期:2016-08-25 发布日期:2016-09-06
  • 通讯作者: 李国强,Tel:021-64723179,E-mail:lgq1258@126.com
  • 作者简介:柏黎明(1982-),男,技师,Tel:021-63601102,

Stress distribution in abutment teeth and related tissues under different design of connector: three-dimensional finite element analysis

BAI Li-ming1, LI Guo-qiang2, ZHANG Qiang1, DONG Xian3   

  1. 1.Department of Prosthodontic Technology, 2.Sino-Japanese Friendship Room, Shanghai Stomatological Hospital. Shanghai 200031;
    3. School of Medical Technology, Shanghai University of Medicine & Health Sciences. Shanghai 201318,China
  • Received:2015-08-10 Online:2016-08-25 Published:2016-09-06

摘要: 目的比较使用同种材料制作的改良设计义齿和常规设计义齿对远中游离端缺损的基牙及相关组织受力的影响。方法选择上颌单侧第一、第二磨牙缺失的55岁男性患者1例,通过螺旋CT扫描、Mimics、Geomagic Studio及ANSYS 软件建模并进行有限元分析,观察基牙及相关组织的受力情况。结果改良设计义齿基牙受力范围明显减小,牙周膜受力减小、鞍基区黏膜受力增加且更均匀,牙槽骨刺激性吸收趋势减小。结论对于远中游离端缺损的牙列缺损患者,改良设计的可摘局部义齿具有一定的应力中断作用,能更好地保护基牙、分散力,对缺牙区黏膜和牙槽骨具有良好的保护作用。

关键词: 三维有限元, 分裂基托式设计, 可摘局部义齿

Abstract: PURPOSE: To compare the stress distribution in abutment teeth and related tissues under the same material and different loading between improved major connector design and traditional major connector design. METHODS: One 55-year-old male patient with unilateral maxillary first molar and second molar missing was chosen. The stress distribution in abutment teeth and related tissues were evaluated with spiral CT scanning, Mimics, Geomagic Studio software, a study model was built and finite element analysis was performed using ANSYS software. RESULTS: With the improved major connector design, the stress of abutment decreased significantly, the stress of periodontal decreased, the stress of edentulous mucosa increased significantly and became more balanced, the trend of stimulated absorption of alveolar bone decreased. CONCLUSIONS: For patients with distal free defect of dentition, the design of improved major connector has the effect of stress interruption, can protect the abutment better, detract the stress of the denture and has an good protective effect on the edentulous mucosa and alveolar bone.

Key words: Three-dimensional finite element analysis, Design of split major connector, Removable partial denture