上海口腔医学 ›› 2015, Vol. 24 ›› Issue (6): 739-742.

• 临床研究 • 上一篇    下一篇

高转矩自锁托槽拔牙矫治上颌前突的效果评价

陈双喜1,唐国华2,蒋雨楠2,顾永佳1,章婷1,高美琴1   

  1. 1.南通市口腔医院口腔正畸科,江苏南通226001;
    2.上海交通大学附属第九人民医院?口腔医学院口腔正畸科,上海200011
  • 收稿日期:2015-06-27 出版日期:2015-12-25 发布日期:2016-01-04
  • 通讯作者: 高美琴, E-mail:ntgmq@126.com E-mail:csx11238@163.com
  • 作者简介:陈双喜1981- , 男,主治医师

Clinical effect of premolar extraction with high torque self-locking appliances

CHEN Shuang-xi1, TANG Guo-hua2, JIANG Yu-nan2, GU Yong-jia1, ZHANG Ting1, GAO Mei-qin1.   

  1. 1.Department of Orthodontics, Stomatology Hospital of Nantong City. Nantong 226001, Jiangsu Province;
    2. Department of Orthodontics, Shanghai Ninth People’s Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine. Shanghai 200011, China
  • Received:2015-06-27 Online:2015-12-25 Published:2016-01-04

摘要: 目的 评价和分析DamonQ高转矩自锁托槽矫治器拔牙治疗上颌前突的临床效果。方法 将40例上颌前突需拔除4颗第一前磨牙进行矫治的患者随机分为2组,Damon组上、下颌均使用DamonQ高转矩自锁托槽矫治器,MBT组上、下颌均使用传统MBT直丝弓矫治器,2组均使用滑动法整体内收上前牙。在治疗前(T0)和上前牙内收完成后(T1)测量2组患者的头颅侧位X线片。采用SPSS 11.5软件包比较2组患者的治疗效果。结果 2组患者在T1时上前牙位置均有明显后移,2组间变化量无显著差异,但上唇位置的后移量Damon组为2.31 mm,显著小于MBT组的2.81 mm(P<0.05)。第一磨牙前移量Damon组为2.33 mm,MBT组为2.36 mm,无显著差异(P>0.05)。T1时,鼻唇角MBT组和Damon组分别为107.44°和106.33°,而鼻唇角增加量MBT组为9.17°,显著大于Damon组的7.22°(P<0.05)。上切牙与腭平面的夹角在T1时MBT组和Damon组分别为110.61°和114.11°,而其减少量MBT组为12.06°,显著大于Damon组的7.61°(P<0.05)。结论 在保证前牙内收效果的基础上,应用DamonQ高转矩托槽拔牙治疗上颌前突患者,在内收前牙阶段与MBT相比,更好地控制了前牙冠唇向转矩,避免了上前牙过度舌倾。

关键词: DamonQ高转矩自锁托槽, MBT直丝弓, 拔牙, 头影测量, 软组织侧貌

Abstract: PURPOSE To analyze the clinical effect of extraction correction of patients with maxillary protrusion by using Damon high torque appliances. METHODS Forty patients with extraction of four first premolars due to orthodontic treatment were selected. They had protrusion of maxilla and were randomly divided into two groups. Both arches of Damon group were treated with Damon high torque appliances and MBT group were corrected with traditional MBT straight wire appliance; patients in two groups received sliding mechanics for adduction of upper anterior teeth. Cephalometric radiophotographs were analyzed before(T0)and after adduction of upper anterior teeth(T1). The difference between the two groups was analyzed with SPSS15.0 software package. RESULTS The upper incisors showed a more retruded position in the two groups at T1,although they showed a similar amount in both groups. The backward movement of upper lip was 2.31mm in Damon group, which was significantly less than that of 2.81mm in MBT group(P<0.05). No significant difference in the first molar mesialization was detected between Damon group(2.33 mm) and MBT group(2.36mm) (P>0.05). For anterior teeth retraction, nasolabial angle (NLA) in MBT and Damon group were 107.44°and 106.33°, increase of NLA in MBT group was 9.17°,which was significantly larger than that of 7.22°in Damon group (P<0.05). U1-MxP in MBT and Damon were 110.61°and 114.11°. U1-MxP decreased 12.06°in MBT group, while significant change was deteced in Damon group of 7.61°(P<0.05).CONCLUSIONS Application of Damon high torque appliances in extraction treatment of maxillary protrusion patients yielded better control of the labial crown torque of anterior teeth, and avoided excessive lingual inclination of anterior teeth compared with MBT in adduction of upper anterior teeth.

Key words: Damon high torque appliances, MBT, Extraction, Cephalometrics, Soft tissue profile

中图分类号: 


版权所有 © 《上海口腔医学》编辑部 沪ICP备17036057号-1
地址:上海市制造局路639号《上海口腔医学》编辑部 邮编:200011
电话:021-53315271 传真:021-63121780 E-mail:shhkqyx@163.com
本系统由北京玛格泰克科技发展有限公司设计开发