牙种植术中钻孔提拉方式及冷却系统对术区温度的影响

刘道杨1, 吴煜农1, 陈宁1, 彭伟2, 廖文清2, 王琰玲1   

  1. 1.南京医科大学口腔医院 口腔颌面外科, 江苏 南京 210029;
    2.浙江工业大学 机械工程学院, 浙江 杭州 310000
  • 收稿日期:2013-06-03 出版日期:2014-04-20 发布日期:2014-05-21
  • 通讯作者: 吴煜农, E-mail:yunongwu@yahoo.com.cn
  • 作者简介:刘道杨(1974-), 男, 在读博士研究生, 主治医师, E-mail:liudaoyang6@163.com
  • 基金资助:
    江苏省高校优势学科建设工程资助项目(2011-137)

The influence of drilling pulling ways and cooling systems on dental implant surgery

LIU Dao-yang1, WU Yu-nong1, CHENG Ning1, PENG Wei2, LIAO Wen-qing2, WANG Yan-ling1   

  1. 1.Department of Oral and Maxillofacial Surgery, Affiliated Stomatological Hospital of Nanjing Medical University. Nanjing 210029, Jiangsu Province;
    2.College of Mechanical Engineering, Zhejiang University of Technology. Hangzhou 310000, Zhejiang Province, China
  • Received:2013-06-03 Online:2014-04-20 Published:2014-05-21

摘要: 目的: 研究牙种植术中不同钻孔提拉方式及不同冷却系统对术区牙槽骨温度的影响, 探讨牙种植术中温度场的变化。方法: 制作48个统一标准的模拟骨块, 根据不同钻孔提拉方式和不同冷却系统分为6组, 每组8个骨块, 进行温度场试验, 测定不同骨块中温度场的温度最高值。采用SPSS12.0软件包对数据进行单因素方差分析。结果: 在相同的钻孔提拉方式下, 内冷却系统温度控制方式术区温度低于外冷却系统的温度控制方式;在相同的冷却系统下, 2次钻孔提拉方式术区温度低于直接1次钻孔方式。其中, 采用内冷却系统进行温度控制时, 2次钻孔提拉方式的术区温度最低(P<0.05)。结论: 牙种植术中采用多次钻孔提拉方式及内冷却系统的温度控制方式, 可以有效降低术区温度, 减少手术产热, 提高牙种植术成功率。

关键词: 牙种植术, 钻孔提拉, 温度控制, 冷却系统

Abstract: PURPOSE: To study the effect of different ways of pulling the drilling burs and cooling systems on alveolar bone temperature of the surgical area, and explore the changes of temperature field in dental implants. METHODS: Forty-eight unified standard artificial (nylon) bone blocks were fabricated and divided into 6 groups according to different drilling pulling ways and cooling systems. The changes of bone temperature field were detected in 6 groups, and the highest temperature in temperature field was measured and recorded. The date was analyzed with SPSS 12.0 software package for ANOVA. RESULTS: The temperature in the surgical area using internal cooling systems under the same drilling pulling was lower than using external cooling systems. The temperature in the surgical area using secondary drilling pulling way was lower than using direct drilling methods under the same cooling systems. The temperature in the surgical area using secondary drilling pulling way was the lowest when internal cooling systems was adopted(P<0.05). CONCLUSIONS: Drilling pulling way and internal cooling systems can effectively reduce the temperature in the surgical area, lessen heat production and improve the success rate of dental implants.

Key words: Dental implant surgery, Drilling pulling, Temperature control, Cooling systems