上海口腔医学 ›› 2020, Vol. 29 ›› Issue (5): 515-518.doi: 10.19439/j.sjos.2020.05.013

• 论著 • 上一篇    下一篇

SanderⅢ矫治器治疗早期骨性Ⅲ类错后软、硬组织变化及垂直向相关性

付雪飞, 邹贤玉, 徐卫华   

  1. 贵州医科大学附属口腔医院 正畸科,贵州 贵阳 550001
  • 收稿日期:2019-08-19 修回日期:2019-11-19 出版日期:2020-10-25 发布日期:2020-11-02
  • 通讯作者: 付雪飞,E-mail:fuxuefei1314520@163.com
  • 作者简介:付雪飞(1976-),女,硕士,副主任医师

Soft and hard tissue changes and vertical correlation of early skeletal Class Ⅲ malocclusion treated with Sander Ⅲ appliance

FU Xue-fei, ZOU Xian-yu, XU Wei-hua   

  1. Department of Orthodontics, Stomatological Hospital of Guizhou Medical University. Guiyang 550001, Guizhou Province, China
  • Received:2019-08-19 Revised:2019-11-19 Online:2020-10-25 Published:2020-11-02

摘要: 目的:探讨SanderⅢ矫治器矫治早期骨性Ⅲ类错后软、硬组织变化和垂直向相关性。方法:选择32例拟行SanderⅢ矫治器矫治的早期骨性Ⅲ类错患者,观察矫治前、矫治12个月后软、硬组织变化,分析软组织与垂直向的相关性。采用SPSS 25.0软件包对数据进行统计学分析。结果:矫治12个月后SNB缩小(P<0.05),ANB、 A-PTV、Go-Me增加(P<0.05),软组织指标LL-LI增加(P<0.05),LL-EP减少(P<0.05),矫治后L1/MP缩小(P<0.05),U1E-PTV增加(P<0.05)。相关性分析显示,UL-UI与倾斜角、U1E-PP、U6E-PP呈正相关(P<0.05),LL-LI与倾斜角、U1E-PP、U6E-PP呈负相关(P<0.05),Sn-UL/FH与U6E-PP呈正相关(P<0.05)。结论:SanderⅢ矫治器可有效矫正早期骨性Ⅲ类错患者软、硬组织畸形,唇部形态随硬组织骨性关系改善而趋于协调,软组织指标与硬组织垂直向关系密切。

关键词: 早期骨性Ⅲ类错, SanderⅢ矫治器;, 软、硬组织, 垂直向

Abstract: PURPOSE: To explore the correlation between the soft and hard tissue changes and the vertical direction of early skeletal Class Ⅲ malocclusion treated with Sander Ⅲ appliance. METHODS: Thirty-two patients with skeletal Class Ⅲ malocclusion who underwent Sander Ⅲ appliance correction were enrolled. The changes of soft and hard tissues were observed before and after treatment for 12 months. The correlation between soft tissue and vertical direction was analyzed. SPSS 25.0 software package was used for statistical analysis. RESULTS: After 12 months of treatment, SNB decreased (P <0.05), ANB, A-PTV, Go-Me increased (P<0.05), soft tissue index LL-LI increased (P<0.05), LL-EP decreased (P<0.05). L1/MP was reduced after treatment (P<0.05), and U1E-PTV was increased (P<0.05). Correlation analysis showed that UL-UI was positively correlated with tilt angle, U1E-PP and U6E-PP(P<0.05); LL-LI was negatively correlated with tilt angle, U1E-PP and U6E-PP (P<0.05). Sn-UL/FH and U6E-PP were positively correlated (P<0.05). CONCLUSIONS: Sander Ⅲ appliance can effectively correct the soft and hard tissue deformity of patients with early skeletal Class Ⅲ malocclusion. The shape of the lip tends to be coordinated with the improvement of hard tissue. The soft tissue index is closely related to the vertical direction of the hard tissue.

Key words: Early skeletal Class Ⅲ malocclusion, Sander Ⅲ appliance, Soft and hard tissue, Vertical direction

中图分类号: